  • Re: Modem communication problem

    Thanks Thorsten  for your reply.  we have configured the same modem in ilon e3 and it worked prfectly fine and was communicating , We have connected it to RS 232 ports only. It was workin fine with Ilon e3 may be say 6 months back . But using the same modem and same typing of configurations and settings done in ILon e3 on smart ...
    Posted to Application Development (Forum) by Abhilash.s on 06-23-2010
  • Modem communication problem

    Hi all, Ffor one of our projects, we are monitoring the energy consumption using meters. we are planning to use a modem (siemens) for GPRS connection to  smart server to send data.  I have connecetd the modem to smart server and done the settings and configurations for the same. But i am getting an error stating " MODEM NOT ...
    Posted to Application Development (Forum) by Abhilash.s on 06-22-2010
  • Re: minimum acess time for smartserver to reduce traffic

    Hi Thorsten   Its an FT channel...
    Posted to Application Development (Forum) by Abhilash.s on 06-16-2010
  • minimum acess time for smartserver to reduce traffic

    Hi all,   we are workin on a poject based on energy management. we are using our own lonworks based energy meters. During recent tetsing by commisioning it in a smart serevr, the smart server shows some random meters as offline . The meters were workin fine for a week and all of a sudden , the smart server shws meters as offline even though ...
    Posted to Application Development (Forum) by Abhilash.s on 06-11-2010
  • Re: Hi everybody

    It is not allowing me access to FTP. Is there any otherway to fix this problem??
    Posted to Driver Development (Forum) by Abhilash.s on 05-02-2010
  • Hi everybody

    I Am facing a problem wherein the smartserver is continously rebooting all the time . it has all the neccesary files loaded into it.. Also over the console port, even if i press the " ! " ket to stop the autobooting, it does not accept and again starts the normal booting procedure. its booting all the time... Can any one help me ...
    Posted to Driver Development (Forum) by Abhilash.s on 04-29-2010
  • How to write program for a pulse

    Hi all,    I have an energy chip which sending me an output in form of pulses. I have connected the output pin of that chip as an IO to nueron chip... i have also written a small code to accept this pulse and display it on smartserver... the prob here is sometimes the server shows the counted pulses andmost of the times it does ...
    Posted to Application Development (Forum) by Abhilash.s on 02-08-2010
  • Re: creating new tempaltes

    Hi Thorsten,  let me make it more clear to you... i actually don want to choose any template from smart server... but wanna create seperately externally and den dump it to smart server... is it possible??  
    Posted to Application Development (Forum) by Abhilash.s on 01-29-2010
  • Re: creating new tempaltes

    Hi Thorsten,  Thanks for your reply.... but what i meant was , wen i create a new device, i don define any template for it. i want to create a seperate template for that new device later after submitting it to smart server. is it possible??
    Posted to Application Development (Forum) by Abhilash.s on 01-26-2010
  • Re: Differnce between normal Modbus protocol and modicon modbus

    Hi Victor,   Thanks for your reply... by MSB i mean the MSb of address location ... for ex in iLon e3, the Modicon mode Address location is for ex ---30001, But the same in iLon smartserver starts with 40001. i want to know why is this diffrence in both MSB of address locations...??
    Posted to Application Development (Forum) by Abhilash.s on 01-20-2010